Table 1 Scan and reconstruction parameters for the 4D-flow measurement

From: Simultaneous measurements of 3D wall shear stress and pulse wave velocity in the murine aortic arch

Parameter HS/LT-res. reconstruction LS/HT-res. reconstruction
Repetition time [ms] 3.0 3.0
Echo time [ms] 1.1 1.1
Flip angle [°] 15 15
Number of readout points 140 140
Number of projections 1.6 ∙ 105 1.6 ∙ 105
Number of velocity Encoding steps 4 (balanced 4-point encoding) 4 (balanced 4-point encoding)
Encoding velocity [cm/s] 125 125
Field of view [mm3] 25 × 25 × 4 25 × 25 × 4
Slab thickness [mm] 4 4
Measurement time [min] 32 (+ 3 min for B0 map) 32 (+ 3 min for B0 map)
Spatial resolution 100 µm 147 µm
N frames per cycle 20 200
Selection window 1/20 1/33
  1. HS/LT high spatial/low temporal, LS/HT low spatial/high temporal
\